Block Storage Disk Performance
The VK Cloud data storage system uses disks of various types:
- HDD;
- SSD;
- High-IOPS SSD;
- High-IOPS HA SSD;
- Low Latency NVMe.
For more information, see the section on block storage disks in VK Cloud.
Each disk type is guaranteed certain performance characteristics. Quotas and limits on the number and size of disks are provided in the article Quotas and limits.
Disk type | Read, IOPS | Read, | Write, IOPS | Write, | Latency, ms |
|---|---|---|---|---|---|
Network HDD disk | 300–2400 | 1 | 150–800 | 1 | 20 |
Network SSD disk | 1000–16000 | 30 | 500–8000 | 15 | 3 |
High-IOPS SSD | 10000–45000 | 30 | 5000–30000 | 25 | 1 |
High-IOPS HA SSD | 7500–35000 | 25 | 2000–12000 | 15 | 1 |
Low Latency NVMe | 10000–75000 | 75 | 5000–50000 | 35 | 0.5 |
Below are detailed performance characteristics for network HDD disks of different volumes.
Size, GB | Read, IOPS | Read, MB/s | Write, IOPS | Write, MB/s |
|---|---|---|---|---|
10 | 300 | 38 | 150 | 19 |
50 | 300 | 38 | 150 | 19 |
100 | 300 | 38 | 150 | 19 |
250 | 300 | 38 | 250 | 31 |
500 | 500 | 63 | 500 | 63 |
1000 | 1000 | 125 | 800 | 100 |
1500 | 1500 | 188 | 800 | 100 |
2000 | 2000 | 250 | 800 | 100 |
Here bs and iodepth are the performance testing parameters.
Below are detailed performance characteristics for network SDD disks of different volumes.
Size, GB | Read, IOPS | Read, MB/s | Write, IOPS | Write, MB/s |
|---|---|---|---|---|
10 | 1000 | 125 | 500 | 63 |
50 | 1500 | 188 | 750 | 94 |
100 | 3000 | 375 | 1500 | 188 |
250 | 7500 | 400 | 3750 | 400 |
500 | 15000 | 400 | 7500 | 400 |
1000 | 16000 | 400 | 8000 | 400 |
1500 | 16000 | 400 | 8000 | 400 |
2000 | 16000 | 400 | 8000 | 400 |
Here bs and iodepth are the performance testing parameters.
Below are detailed performance characteristics for network High-IOPS SSD disks of different volumes.
Size, GB | Read, IOPS | Read, MB/s | Write, IOPS | Write, MB/s |
|---|---|---|---|---|
10 | 10000 | 500 | 5000 | 500 |
50 | 10000 | 500 | 5000 | 500 |
100 | 10000 | 500 | 5000 | 500 |
250 | 10000 | 500 | 6250 | 500 |
500 | 15000 | 500 | 12500 | 500 |
1000 | 30000 | 500 | 25000 | 500 |
1500 | 45000 | 500 | 30000 | 500 |
2000 | 45000 | 500 | 30000 | 500 |
Here bs and iodepth are the performance testing parameters.
Below are detailed performance characteristics for network High-IOPS HA SSD disks of different volumes.
Size, GB | Read, IOPS | Read, MB/s | Write, IOPS | Write, MB/s |
|---|---|---|---|---|
10 | 7500 | 375 | 2000 | 250 |
50 | 7500 | 375 | 2000 | 250 |
100 | 7500 | 375 | 2000 | 250 |
250 | 7500 | 375 | 3750 | 300 |
500 | 12500 | 375 | 7500 | 300 |
1000 | 25000 | 375 | 12000 | 300 |
1500 | 35000 | 375 | 12000 | 300 |
2000 | 35000 | 375 | 12000 | 300 |
Here bs and iodepth are the performance testing parameters.
Below are detailed performance characteristics for local Low Latency NVMe disks of different volumes.
Size, GB | Read, IOPS | Read, MB/s | Write, IOPS | Write, MB/s |
|---|---|---|---|---|
10 | 10000 | 500 | 5000 | 500 |
50 | 10000 | 500 | 5000 | 500 |
100 | 10000 | 500 | 5000 | 500 |
250 | 18750 | 586 | 8750 | 500 |
500 | 37500 | 1172 | 17500 | 547 |
1000 | 75000 | 1200 | 35000 | 900 |
1500 | 75000 | 1200 | 50000 | 900 |
2000 | 75000 | 1200 | 50000 | 900 |
Here bs and iodepth are the performance testing parameters.
-
Before testing, make sure that the following conditions are met:
- the disk is non-bootable;
- there is no load on the disk from the operating system.
If these conditions are met, the IOPS measurement results should match the following values:
Test type
Result, IOPS
Read and write with 4 KB blocks in 32 threads
Matches the SLA
Read and write with 8 KB blocks in 32 threads
At least 75% of the SLA
Read and write with 16 KB blocks in 32 threads
At least 50% of the SLA
-
Test the disk.
WindowsLinuxTo measure IOPS for reading and writing, use the DiskSpd or FIO utilities.
DiskSpd
-
Run the command prompt as administrator.
-
Create a
tempdirectory and an empty file of at least 10 GB:md C:\tempfsutil file createnew C:\temp\test.bin 10485760000 -
Download the utility and extract it to the desired directory.
-
Navigate to the
amd64directory of the extracted utility. -
Run the
diskspdcommand with parameters corresponding to the test type:-w— percentage of write operations,-w0for a read test,-w100for a write test;-b— block size in bytes.
For a detailed description of all
diskspdcommand parameters, see the official documentation.-
Random write test with 4 KB blocks:
diskspd -Suw -b4K -o1 -t32 -r -w100 C:\temp\test.bin > C:\temp\random_write_results.txt -
Random read test with 4 KB blocks:
diskspd -Suw -b4K -o1 -t32 -r -w0 C:\temp\test.bin > C:\temp\random_read_results.txt
FIO
-
Download and install FIO.
-
Run the
fiocommand with parameters corresponding to the test type:--rw—randreadorrandwrite.--bs— block size.--filename— name of the test file.--rate_iops— target IOPS value (optional). Use this parameter to obtain a more accurate latency value when testing the target IOPS value.
For a detailed description of all command parameters, see the FIO documentation.
-
Random write test with 4 KB blocks:
PowerShellCommand promptfio `--name=randwrite `--iodepth=32 `--rw=randwrite `--bs=4k `--direct=1 `--size=10G `--numjobs=1 `--runtime=240 `--group_reporting `--filename=C:\Users\ADMIN\test -
Random read test with 4 KB blocks:
PowerShellCommand promptfio `--name=randread `--iodepth=32 `--rw=randread `--bs=4k `--direct=1 `--size=10G `--numjobs=1 `--runtime=240 `--group_reporting `--filename=C:\Users\ADMIN\test
-
-
If, after meeting all the conditions, the test results do not match the specified values, contact technical support.
-
After testing is completed and the results are processed, delete the large test files to free up disk space. Quotas and limits on the use of VK Cloud resources are provided in the article Quotas and limits.